CIP RC/PT Girder Help

Truck/Lane Live Load & Combination Min/Max Reaction Report

Note: This report is identical for Pedestrian loadings.

The Support column shows the label associated with the support. The Location column shows the physical location of the support on the box girder in relation to the start of the girder. The first two Max and Min columns show the maximum and minimum horizontal reaction.

The second two Max and Min columns show the maximum and minimum vertical reaction. Below these results is the corresponding moment and below that is the corresponding horizontal force associated with the location of the truck (or portion of the influence line for lane loading).

The third Max and Min columns show the maximum and minimum moments. Below these results is the corresponding vertical force and below that is the corresponding horizontal force associated with the location of the truck (or portion of the influence line for lane loading).